Syrris logo

English | Deutsch (NEU) | 日本語 | Português

SitemapSitemap
VideosVideos
SupportSupport
  • Homepage
  • Company
    • History
    • Testimonials
    • Syrris for Beginners
    • Careers
    • Syrris Customers
    • Awards and Accreditations
  • Batch Products
    • Atlas Overview
    • Atlas Jacketed Reactors
    • Atlas Calorimeter
    • Atlas Pressure Reactors
    • Atlas Flasks and Vials
    • Atlas Parallel Systems
    • Atlas Syringe Pump
    • Atlas Software Overview
    • Batch Reactor Catalogue
    • Globe Chemical Reactor
    • Custom Reactor Overview
    • Reactor Master
    • Bioisostere Software
  • Flow Products
    • Asia Flow Chemistry
    • Asia Manual Systems
    • Asia Automated Systems
    • Asia Process Optimization
    • Asia Modules
    • Asia Catalogue (Parts)
    • Africa Flow Chemistry
    • Africa Modules
    • Africa Accessories
    • FRX Flow Chemistry
  • Applications
    • Flow Chemistry
    • Discovery / Medicinal
    • Reaction Calorimetry
    • Process Chemistry
    • Crystallization
    • Other Applications
  • News
    • News
    • Latest Events
    • E-Newsletters
    • Syrris in Publications
  • Contact Us
    • Syrris Group Offices
    • Local Distributors
    • Who can I talk to?
  • Downloads
Chemistry Applications
Home Applications Discovery / Medicinal Parallel Chemistry
  • Flow Chemistry
  • Discovery / Medicinal
    • Parallel Chemistry
    • Library Synthesis
    • Aqueous Work-Up
    • Log D
  • Reaction Calorimetry
  • Process Chemistry
  • Crystallization
  • Other Applications

Parallel Chemistry - Syrris

Parallel Chemistry

Atlas_with_triple_dry_bath_no_posts_200_wide

The Triple Drybath Reactor - Parallel Chemistry in Flasks

orbit_12_with_Reflux_200

Atlas Orbit 12 Parallel Reaction Station

Vial_Bath_Complete_small_200

An Atlas Vial Bath for Heating and Cooling Reaction Vials

Parallel Chemistry

Parallel chemistry is used in medicinal chemistry to syntheise a number of analogues of compounds at the same time. This is typically done by performing the same type of reaction and applying the same reaction conditions to a number of reactors (flasks/vials/tubes etc.) but varying the substrates or reagents.

The Syrris Atlas system allows parallel chemistry to be performed in round bottom flasks, refluxing reactor tubes, pressurisable reaction vials or open reaction vials.

Round bottom flasks

For high performance parallel chemistry in round bottom flasks, many Atlas bases can be controlled in parallel either with or withot PC control. Many reactors can be controlled simultaneously either running the same reaction profile or varying parameters such as temperature, reagent added, pH, reaction time etc.

A lower cost alternative for parallel round bottom flask applcations where the same temperature and stirring speed are required, is the Triple Dry Bath (and Triple Clamp). The Triple Dry Bath allows up to 3 round bottom flasks from 50ml to 250ml to be heated or cooled in parallel.

Reaction Tubes with Reflux

The Atlas Orbit allows 6 or 12 reaction tubes to be magnetically stirred in an inert atmosphere and be heated to 280°C with reflux or cooled to -40°C. Reagents can be added through the septum. It fits conveniently on an Atlas hot plate, Atlas Hot and Cold plate or regular hotplate.

The Atlas Orbit is available in two sizes: 6 tubes (24mm Ø, 45ml) and 12 tubes (13mm Ø, 10ml). Each tube size has a corresponding cap with septum. The novel nature of the Orbit means that as the Orbit lid is clicked in place, the inert atmosphere is applied to all the tubes simultaneously.

When the lid is removed, the septa are automatically re-sealed and the tubes are free to be transported. The unique design also allows the gas and water supplies to remain connected to the reflux unit whilst the tubes are transported in the Orbit.

Pressurisable or Open Reaction Vials

The Atlas Vial Baths are a new way of heating or cooling several reaction vials at the same time. Designed to fit on standard hotplate stirrers, these Vial Baths provide good thermal contact to the vial and therefore excellent temperature control within the reaction.

Each of the Vial Bath inserts is interchangeable within the Dry Bath Base making changing vial size quick and easy. The exterior of the Dry Bath remains safe to touch even when the Vial Bath is hot or cold

Flow chemistry

Flow chemistry, though not generally considered parallel in the strict definition of the term allows "rapid series" experiments to be performed where many different chemistries to be performed in rapid succession without changing apparatus. Library synthesis in flow offers significant advantages over batch approaches. Further details on flow chemistry can be found in the flow chemistry application area.