Walk-away dosing and sampling
- Versatile volumetric dosing and/or sampling
- Universally compatible with any reactor system
- Temperature-dependent & pH controlled dosing
Works with your system
The standalone Atlas Syringe Pump is universally compatible with any chemical reactor and can handle a wide range of chemicals. Whether you need to dose, sample, or both, the Atlas Syringe Pump is the ideal solution.
Two different sizes of Atlas Syringe Pump mean that scale is no limiting factor:
Atlas Syringe Pump Standard pumps up to 20 mL/min
Atlas Syringe Pump XL pumps up to 200 mL/min
See the full breakdown of flow rates and syringe sizes below.

The only pump you need
The Atlas Syringe Pump can save you time and money, no matter your chemistry. Featuring multiple operation modes, it can deliver continuous flow, dose up to 10 reagents to one reactor, or supply multiple reactors simultaneously. You can even dose as many as 10 reactors from a single Atlas Syringe Pump.

Accurate, precise, and efficient
Excellent chemical compatibility, a wide flow range, incredible accuracy of 0.20% coefficient of variation (Cv), and precision of 0.06% (Cv) mean that the Atlas Syringe Pump is ready for any chemical process. Its compact size, easy-to-use design, and powerful data logging and processing make it a reliable addition to your lab. Reliable operation and data, whenever you need it.

Works smart
Make even the most complex processes simple with Atlas Syringe Pump’s intelligent dosing modes.
pH controlled dosing lets you automatically dose an acid and/or base to keep the pH or your reaction within a defined range.
Automated Temperature-dependent dosing allows you to define the temperature range at which your reagents are dosed and automatically mitigates against exotherms and endotherms, increasing laboratory safety and saving valuable time.

Three control modes
Complex automation of dosing and sampling is achievable using any of the three control modes.
- Manual – Integrated twist and-click control and a large LCD display
- Atlas PC Software – Control and automates experiments, data collection, and perform data analysis with Atlas PC Software
- Atlas HD Automated Reactor – Seamless integration with Atlas HD Automated Reactor

Autosampler Module
The Autosampler Module is designed for use with the Atlas Syringe Pump or Atlas Syringe Pump XL and Autosampler Probe to aspirate up to 6 samples (when using 6 port valves) from a reactor at user defined intervals.

Customer story: using Atlas Syringe Pumps for gold nanoparticle production
Researchers at Midatech Biogune, a Spanish biotechnology company, are using Syrris Atlas Syringe Pumps with Atlas automated jacketed reactor systems to produce custom-made functionalized gold nanoparticles for medicinal use.
Our Atlas HD jacketed reactors, with pH control and an Atlas XL Syringe Pump, have allowed us to scaleup production, enabling variables such as pH and temperature to be tightly controlled”



-
Atlas Syringe Pump specifications
Universal dosing and sampling Works with any reactor Self-refilling continuous dosing Dual syringes refill without interrupting continuous flow Automated pH Control Keeps pH within a defined range Excellent chemical compatibility Dose what you want when you need to. Autosampling Automated sampling of up to 6 samples with each syringe Multiple automated dosing modes Multiple reagent dosing to multiple reactors 3 modes of control Manual, Atlas PC Software, or Atlas HD Automated Reactor integration Wide Flow range 0.5 μl/min to 20 ml/min standard pump and up to 200 ml/min with XL pump Automated Temperature-dependent dosing For enhanced control of exothermic reactions Accurate & precise Accuracy of 0.20% Cv and precision of 0.06% Cv Compact and mobile At a space saving 23cm wide, it fits any space Multiport valves A range of no-tool, easy to fit multiport valves Multiple Syringe Sizes A range of no-tool, easy to fit syringes in varying sizes -
Multiple dosing and sampling modes
Automated reagent addition Dose by volume or flow rate over a time period or create advanced flow profiles. Simultaneous dosing and autosampling Each channel doses or samples independently within a defined parameter range Single continuous flow addition Both channels work together for one stable flow 10 reagents to one reactor Five reagents through each channel One reagent to 10 reactors One reagent pumped through both channels Five reagents to one reactor x2 Five reagents pumped through each channel to individual reactors One reagent to five reactors x2 One reagent pumped through each channel to five reactors -
Flow rate range and syringe sizes for the Atlas Syringe Pump
Flow rate range for the Atlas Syringe Pump Min flow rate μL/min Max flow rate μL/min Syringe size (μL) Continuous flow Dual dose mode Continuous flow Dual dose mode 50 10 0.5 200 200 100 20 1 400 400 250 50 2.5 1000 1000 500 100 5 2000 2000 1000 200 10 4000 4000 2500 500 25 10000 10000 5000 1000 50 20000 20000 -
Flow rate range and syringe sizes for the Atlas XL Syringe Pump
Flow rate range for the Atlas XL Syringe Pump (in mL) Min flow rate mL/min Max flow rate mL/min Syringe size (mL) Continuous flow Dual dose mode Continuous flow Dual dose mode 0.5 0.1 0.005 2 2 1 0.2 0.01 4 4 2.5 0.5 0.025 10 10 5 1 0.05 20 20 10 2 0.1 40 40 25 5 0.25 100 100 50 10 0.5 200 200
What our customers say
Thanks again for your support! The pump arrived yesterday; it runs quietly, smoothly and the user interface is – as you said – straightforward. The size and design fit perfect to our needs and I love the metal finish.
